Built-up steel sections are assembled from standard shapes, plates and angles. SAFI™ structural analysis calculates their properties with a finite-element approach, lets you set their section class, and checks them like any other steel member, including torsion and warping.
- Capped and reinforced, boxed and plated, and angle-made shapes are available.
- J, Cw and the shear center are computed on a finite-element mesh, not with approximate formulas.
- The engineer sets the section class; if none is set, the section is treated as noncompact.
- Connecting plates can be modeled as continuous plates or diagonal lacing.
What Is a Built-Up Steel Section?
A built-up section is assembled from source sections, plates or other steel shapes. Its properties come from the dimensions and properties of each source section, the plates used, and the geometry of the assembly.
Once created, the built-up section can be assigned to members like any other steel section. When a source section changes, re-edit the built-up section and click Recalculate Properties.
Built-Up Shapes Available
Built-up shapes come in three families: capped and reinforced shapes, boxed and plated shapes, and shapes made of angles.
- I shape with C cap
- C shape with C cap
- I shape with I cap
- I shape with reinforcing plates
- Rectangular tube with reinforcing plates
- C shape box, back to back
- C shape box, toe to toe
- I shape box
- I shape with lateral plates
- Plate box
- C shape made of angles
- I shape made of angles
- Star shape made of angles
Creating and Editing a Built-Up Section
- Open Table › Sections › Built-Up Sections.
- Click Add a new tab and choose the assembly shape.
- Select the source sections and plates.
Editing built-up properties
Built-up properties are calculated by the program and cannot be edited directly. To make an editable copy, open Table › Sections › User defined section, click Add a new tab and choose Import built-up section. All properties of the resulting user-defined section can then be modified.
Finite-Element Calculation of Section Properties
All properties are calculated with a general finite-element approach, rather than the simplified approximate equations found in references, which are not available for complex shapes. The automatic mesh gives particularly good precision, and the Preview Mesh button displays the mesh used in the calculations.
Calculated section properties
| Property | Description |
|---|---|
| A | Cross-section area |
| Agw | Cross-section area for weight |
| Ixx | Strong-axis moment of inertia, ∫y² dA |
| Iyy | Weak-axis moment of inertia, ∫x² dA |
| J | Torsional constant, computed from the warping function |
| Cw | Warping constant |
| Ct | Torsional stress constant: τt = Mxp / J · Ct (Mxp = pure torsion moment) |
| X0, Y0 | Shear center coordinates relative to the centroid |
| α | Angle between the principal axes and the straight axes |
| Sx,min, Sy,min | Elastic section moduli, Ix / ymax and Iy / xmax |
| Zx, Zy | Plastic section moduli, ∫y dA and ∫x dA |
| Cs,z, Cs,y | Shear stress constants: τxz = Vz / Iy · Cs,z and τxy = Vy / Iz · Cs,y |
| βx | Coefficient of asymmetry, 2Y0 + (1/Ix) ∫y(x² + y²) dA; its sign changes with the compressed flange |
| rs | Radius of gyration of the built-up components, √(Is / As) |
| Aw,x, Aw,y | Effective shear areas, ks · A |
| ks,x, ks,y | Shear deflection constants |
| rt,top, rt,bot | Radii of gyration of the top and bottom flanges |
| Iyc,top, Iyc,bot | Weak-axis inertias of the top and bottom flanges |
The flange values (rt and Iyc) include the compressed flange plus one-third of the compressed part of the web, about the weak axis. They are used for lateral-torsional buckling of singly symmetric sections.
Section Classification and Limit-State Design
Limit states are available for all built-up sections, but the engineer must specify the section class, separately for compression, positive bending, negative bending and weak-axis bending. If no class is specified, the section is treated as noncompact by default. For slender sections, the effective properties must also be entered, as defined by the selected design code.
| Section class | How it is used |
|---|---|
| Unknown / No design | Resistances and the related limit states are not calculated. |
| Plastic and compact | Can reach yield across the whole section before local buckling. Bending uses the plastic moduli (Zx, Zy). |
| Noncompact (default) | Can reach yield on part of the section before local buckling. Bending uses the elastic moduli (Sx, Sy). |
| Slender | Walls may buckle before yield. Uses the effective properties you enter, per the design code. |
Classification is not automated for built-up sections. A dedicated button shows the class of each component as if it were unattached, based on its material and the selected design code. Connectors also affect the classification and must be considered by the engineer.
Built-up sections are checked for bending, compression, tension, shear, torsion, warping and combined resistance, like other steel members, with the steel design codes below. See also torsion and warping analysis.
Continuous Plates and Diagonal Lacing
The Consider plates as option sets whether the connecting plates are continuous plates or diagonal lacing. It appears only for shapes that can use plates or diagonal elements.
With diagonal lacing, these properties are calculated without the plates: A, Ixx, Iyy, Sx,min, Sy,min, Zx, Zy, rt,top, rt,bot, Iyc,top and Iyc,bot. A plate of equivalent thickness must still be defined; it is used for the other properties.
Advanced Section Stress Analysis
To see the stress distribution in a built-up section, go to Analysis › Charts › Analysis and select Advanced section stress analysis or Advanced member stress analysis. These show the stress distribution in the section at each calculation point along the members.
These results come from a finite-element analysis of the section and may differ slightly from the results of the Internal stresses command.
Video: Built-Up Sections
Frequently Asked Questions
How are built-up section properties calculated?
With a general finite-element approach on a mesh of the section, rather than approximate equations. This includes J, Cw and the position of the shear center.
Who sets the class of a built-up section?
The engineer, separately for compression, positive bending, negative bending and weak-axis bending. If no class is set, the section is treated as noncompact.
Can I edit the properties of a built-up section?
Not directly. Import the built-up section into a user-defined section (Table › Sections › User defined section › Import built-up section), and all its properties can then be modified.
Learn More
Structural Analysis
Design Built-Up Steel Sections with Confidence
Finite-element section properties, section classes, plates or lacing, and full steel verification including torsion and warping.