Live Load ReductionAutomatic Column Live Load Reduction to NBCC, ASCE 7 or Custom Methods in GSE™

How the GSE™ steel, concrete, aluminum and wood modules reduce the live loads on columns, calculate the live load reduction factor (LLRF) and use the effective compression force in design.

Live loads on the columns of a structure can be reduced automatically in GSE™, according to the selected method. The live load reduction factor (LLRF) lowers the effective axial compression force used to design the columns.

In short
  • Available for the steel, concrete, aluminum and wood modules of GSE™.
  • Applied to the columns of the structure.
  • Methods: NBCC, ASCE 7, Custom (By Tributary Area) and Custom (By Supported Storeys).
  • The tributary area is calculated separately for each reducible live load.

Automatic Live Load Reduction for Columns in GSE™

Live load reduction can be used with the GSE™ Steel, GSE™ Concrete, GSE™ Aluminum and GSE™ Timber (wood) modules. It is applied to the columns of the structure: GSE™ calculates the live load reduction factor (LLRF), which reduces the effective axial compression force in the columns.

Effective Compression Force with Reduced Live Loads

Live load reduction offCf is equal to Cf (ana), the force from the analysis.
Live load reduction onCf is the effective compression force.

For each combination used in the compression limit states design, the effective compression force Cf (positive for compression) is calculated with:

Cf = Cf (ana) − Σi=1…n [ −α · Li · Fxi · (1 − LLRFi) ]
Cf
effective compression force (positive for compression)
Cf (ana)
compression force from the analysis, without reduction
Fxi
unfactored axial force of the reducible basic load i (positive for tension)
−α · Li · Fxi
factored compression force of the reducible live load i (positive for compression)
LLRFi
live load reduction factor of the reducible live load i
n
number of reducible basic live loads in the combination

Live Load Reduction Factor (LLRF) Methods: NBCC, ASCE 7 and Custom

The live load reduction factor is calculated with the selected method, where A is the tributary area:

MethodLive load reduction factor (LLRF)
NBCC0.3 + √(9.8 / A)  or  0.5 + √(20 / A)
ASCE 70.25 + 15 / √(KLL · A) ≤ 1
Custom (By Tributary Area)a + b / √A ≤ 1  ·  a + b / A ≤ 1  ·  1 − a (A − b) ≤ 1
Custom (By Supported Storeys)Reduction based on the supported storeys
No reductionDefault setting

For the custom methods, a and b are parameters defined by the user.

How to Apply Live Load Reduction in GSE™

  1. Create the reducible live loads. Create the basic loads with the “Reductible Live Load” type in the software. For NBCC, the “Reductible Live Load (NBCC Assembly)” type is also available. Several reducible live loads can be used, each with its own tributary area.
  2. Define the method. In Tables › Live Load Reduction, choose NBCC, ASCE 7, Custom (By Tributary Area) or Custom (By Supported Storeys).
  3. Activate the method. In Analysis › Codes and Standards, select the Live Load Reduction Method in the tab of each material. No reduction is active by default.
  4. Define the storeys. In Edit › Storeys.
  5. Change the method for some members (optional). In the member attributes, edit the Live Load Reduction method in the material tab.
  6. Run the analysis with the appropriate design option.

Tributary Area, LLRF and Column Design Results

ResultWhere to find it
Tributary areas and LLRF (numerical)Analysis › Numerical Results › Analysis › Member Tributary Area
Tributary areas and LLRF (charts)Analysis › Charts › Analysis › Column Tributary Area
On the structureAnalysis › Global Curves › Analysis › Options, then select the basic loads with the Basic Loads button
Design forcesCompression and compression/bending limit states tables of each GSE™ module, showing both Cf (ana) and Cf when the LLRF is less than 1.0

Frequently Asked Questions

Which GSE™ modules use live load reduction?

Live load reduction is available for the steel, concrete, aluminum and wood modules of GSE™, and it is applied to the columns of the structure.

Which live load reduction methods are available?

NBCC, ASCE 7, Custom (By Tributary Area) and Custom (By Supported Storeys). No reduction is the default setting.

What is the effective compression force Cf?

Without live load reduction, Cf equals Cf (ana), the force from the analysis. With live load reduction, Cf is the effective compression force, obtained by removing the reduced part of each reducible live load in the combination.

Is live load reduction active by default?

No. The method is activated in Analysis > Codes and Standards, in the tab of each material, and it can be changed for individual members in the member attributes.

How can the tributary areas and LLRF be checked?

In Analysis > Numerical Results > Analysis > Member Tributary Area, or graphically in Analysis > Charts > Analysis > Column Tributary Area. The compression limit states tables show both Cf (ana) and Cf when the LLRF is less than 1.0.

Can several reducible live loads be used in the same model?

Yes. Several reducible live loads can be defined, and the tributary area is calculated separately for each reducible live load.

Can a different live load reduction method be used for some columns?

Yes. The method is activated globally in Analysis > Codes and Standards, and it can be changed for individual members in the member attributes, in the material tab.

Is there a specific NBCC live load type?

Yes. For NBCC, a Reductible Live Load (NBCC Assembly) basic load type is available in addition to the Reductible Live Load type.

Learn More

GSE™ Software

Reduce Column Live Loads Automatically

NBCC, ASCE 7 or custom methods, tributary areas per reducible load and the effective compression force in design.

GSE™ Features

TECHNICAL FEATURE // LIVE LOAD REDUCTION

The live load reduction is available for the GSE™ steel, concrete, aluminum, and wood modules. The live load reduction will be applied to the columns of the structure. Live loads can be automatically reduced according to the selected method. The software computes the live load reduction factor (LLRF) that will reduce the effective axial compression force in columns.

When there is no live load reduction, Cf is equal to Cf (ana).

When the live load reduction is enabled, Cf is the effective compression force.

For a specific combination used in the compression limit states design, the effective compression force Cf (positive value for compression) will be computed based on the following equation.

Picture of GSE™ Software

GSE™ Software