Some members have dimensions that change along their length. SAFI™ structural analysis models them with variable inertia sections, built from source sections placed along the member.
- A variable section is defined by source sections placed at positions along a physical member.
- Each dimension is interpolated, and the section properties are recalculated from the interpolated dimensions.
- Interpolation can be linear, quadratic or cubic.
- The physical member must be subdivided before the analysis.
What Are Variable Inertia Sections?
A variable section is a section whose dimensions vary along a physical member. Each dimension of the section is interpolated along the member, and the section properties are then recalculated from the interpolated dimensions. When the properties of the source sections have been modified by the user, the recalculated properties are corrected accordingly.
Defining a Variable Section
- Create the source sections. Create non-standard sections that match the known dimensions of the member at given points along its length.
- Assign each source section to a position. Enter each source section in a Section field and its location in the matching Position field.
- Choose the interpolation type. The number of source sections needed depends on the interpolation type.
All source sections must be of the same section type and dimensionally compatible. The section type is set by Section #1.
Positioning the Source Sections
The Method of positioning sets how the positions are measured along the member:
Positions can be negative or greater than the member length, and the source sections do not have to be located at the ends of the member. For example, a variable section can be defined between 0.1L and 0.9L.
Interpolation Types
Viewing Dimensions and Properties
The variable section can be previewed over its full length. Its dimensions and properties at a specific position are displayed by clicking on the profile graph or by entering the position in the Edition field.
Constant and Interpolate Display Options
| Display option | Section properties | Used for |
|---|---|---|
| Constant | Constant-inertia segments, with properties calculated at the centre of each member | Structural analysis, and resistance of steel and aluminum members |
| Interpolate | Properties linearly interpolated along each member | Resistance calculations of reinforced concrete members |
Subdividing the Member
To use a variable section, the physical member must be subdivided. The Subdivide Member command can be used at any time before the analysis. The technical paper compares the bending moment diagrams of a member subdivided into 2, 5 and 10 divisions.
Frequently Asked Questions
How many source sections does each interpolation type need?
Linear interpolation needs at least 2 source sections and can use more, forming several linear segments. Quadratic interpolation needs 3 source sections and cubic interpolation needs 4.
What is the difference between relative and absolute positioning?
With relative positioning, positions are a ratio of the member length, so the profile follows the length of the member. With absolute positioning, positions are distances from the start of the member, so the profile is independent of the member length.
Must the member be subdivided to use a variable section?
Yes. A physical member must be subdivided to use a variable section. The Subdivide Member command can be used at any time before the analysis.
Which display option is used for steel, aluminum and reinforced concrete?
The Constant option, with properties calculated at the centre of each member, is used for the structural analysis and for the resistance of steel and aluminum members. The Interpolate option, with properties linearly interpolated along each member, is used for reinforced concrete resistance calculations.
Learn More
Structural Analysis
Model Members with Variable Sections
Source sections interpolated linearly, quadratically or cubically, with properties recalculated along the member.